High-Temperature Chamber Furnaces with Electric or Gas Heating
HT 16/17 HT 160/17 with cooling fan, automatic vapor air flap control, and start-up circuit

Parallel motion swivel door for lasting protection of the collar insulation against destruction

Reinforced floor as protection for bottom insulation HT 32/16

Gastight retort with gas injection through the furnace floor

HTB 645/17 with fuel heating

Gass heating system

HT 04 - HT 450

The HT 04/16 ff. fibre insulated high-temperature furnaces are the ideal choice for sintering special glass, e.g. quartz glass or for melting trials in the laboratory. Excellent temperature uniformity, solid construction provide for the necessary competitive edge with resprect to quality (tabletop models see laboratory catalog).

  • Tmax 1600 °C, 1750 °C, or 1800 °C
  • Furnace sizes from 4 to 450 liters
  • High-quality molybdenum disilicide (MoSi2) heating elements
  • Parallel swivel door, chain-guided, enabling safe opening and closing without damage to the fibre insulation in the collar area, protection of user from radiation from the furnace
  • Door labyrinth sealing provides for optimum energy efficiency and temperature distribution
  • Door area armored with stainless steel to avoid burn damages
  • Reinforced floor as protection for bottom insulation as standard from models HT 32/16 upwards
  • Over-temperature limit controller with manual reset for product and furnace protection
  • Furnace chamber lined with first-class, durable fibre material
  • Special ceiling construction with high durability
  • Thermocouple, PtRh-Pt, Type B or Type S
  • Vapor vent in the furnace roof

Additional equipment

  • Cooling fan For cycle time acceleration furnace sized specific fans are installed. The fan speed is preselected per segment. The controller is automatically switched on and off. Hence, different speeds can be applied e.g. for binder removal or cooling. With HiProSystems-Controllers, lenear cooling is possible.
  • Furnace in HDB design featuring fresh air pre-heating, exhaust gas ventilation and an extensive safety package for debinding and sintering in one process, i. e. without transfering the material from the debinding furnace to the sintering furnace.
  • Automatic control of vapor vent flaps
  • Stainless steel exhaust gas hoods
  • Catalytic or thermal afterburners
  • Kiln furniture tailored to customer specifications
  • Lift door
  • Protective gas connector and seal of furnace casing to allow purging of furnace with protective gasses
  • Manual or automatic gas supply system
  • Retort to improve the gastightness and to protect the furnace chamber against contamination
Gas-heated Chamber Furnace HTB

Besides our wide range of electrically heated high temperature chamber furnaces we can also offer gas heated models designed to suit your requirements. Please contact us.

ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmSupplyElectricalWeight
 °Cwdhin lWDHpower/kWconnections*in kg
HT 04/161600150150150461047014005,23-phase¹150
HT 08/161600150300150861061014008,03-phase¹200
HT 16/16160020030026016710650150012,03-phase¹270
HT 32/16160020060026032710930150018,03-phase350
HT 40/16160030035035040810710161012,03-phase380
HT 64/161600400400400641020840170018,03-phase550
HT 128/16160040080040012810201250170026,03-phase750
HT 160/16160050055055016011401020190021,03-phase800
HT 276/161600500100055027611401470190036,03-phase1100
HT 450/161600500115078045011401620206064,03-phase1500
            
HT 04/171750150150150461047014005,23-phase¹150
HT 08/171750150300150861061014008,03-phase¹200
HT 16/17175020030026016710650150012,03-phase¹270
HT 32/17175020060026032710930150018,03-phase350
HT 40/17175030035035040810710161012,03-phase380
HT 64/171750400400400641020840170018,03-phase550
HT 128/17175040080040012810201250170026,03-phase750
HT 160/17175050055055016011401020190021,03-phase800
HT 276/171750500100055027611401470190036,03-phase1100
HT 450/171750500115078045011401620206064,03-phase1500
            
HT 04/181800150150150461047014005,23-phase¹150
HT 08/181800150300150861061014009,03-phase¹200
HT 16/18180020030026016710650150012,03-phase¹270
HT 32/18180020060026032710930150018,03-phase350
HT 40/18180030035035040810710161012,03-phase380
¹Heating only beetween two phases *Please see page 42 for more information about mains voltage

More information

Print

Glass glas_englisch

 
 
High Temperature Top-Hat and Elevator Furnaces
 
 Elevator-type furnace HT 64/17 LBS with additional insulation of the casing for melting glass HT 400/17 LTS with interchargeable tables as additional equipment

Open furnace at 1600 °C with lowered table

HT 64/16 LB - HT 276/17 LTS

In order to fulfill the high demands regarding a good temperature uniformity, high temperature top-hat and elevator furnaces are used. In the LB version the hat is stationary and the table is mobile. This layout is only recommended if furnace must be opened hot. As additional equipment for opening in hot condition the furnace frame is additionally insulated in order to avoid burns of the system. The LT version with mobile top-hat and stationary table is recommended when sensitive settings are charged.

Standard version different from chamber furnaces HT 04/16 ff.

  • Design as top-hat or elevator furnace (lift-top or lift-bottom principle)
  • Standard furnace size ranging from 64 to 276 liters
  • Electrical top-hat or table spindle drive practically free of vibration
  • Furnace closes safely and tightly due to a labyrinth-sealing and additional sand sealing
  • Floor reinforcement for heavy loads with level stack charging provides for protection of the fiber insulation

Additional equipment different from chamber furnaces HT 04/16 ff.

  • Exchangeable table system with second table
  • Electrical table drive
  • Automatic control of all movements
  • Insulated furnace rack for hot opening, i. e. for melting glass, for instance
ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmSupplyElectricalWeight
 °Cwdhin lWDHpower/kWconnections*in kg
HT 64/.. LTS1600
or
17504004004006495017002450393-phase1300
HT 166/.. LTS550550550166110021002500473-phase1500
HT 276/.. LTS1000500550276160021502500743-phase2000
HT 400/.. LTS1200600550400180022502500763-phase2700
*Please see page 42 for more information about mains voltage

More information

Print

catalogue Glass glas_englisch

 
 
High-Temperature Furnaces HFL as floor Models with Brick Insulation for Melting Experiments
 
 HFL 160/17 with gas supply system HFL 295/13 with lift door and transformer in stand, with customer-specific design

Protective screen in front of heating elements for protection against mechanical damage

HFL 16/16 - HFL 160/17

Model range HFL 16/16 HFL 160/17 is characterized by its lining with robust light refractory bricks. This version is recommended for processes producing aggressive gases or acids, such as under glass melting.

  • Tmax 1600 °C or 1700 °C
  • High-quality molybdenum disilicide (MoSi2) heating elements
  • Insulation with light refractory bricks and special backup insulation
  • Type B thermocouple
  • Furnace sizes of 16 to 160 liters
  • For the release of vapours, a 30 mm large exhaust hole is integrated into the roof of the furnace
  • Over-temperature limit controller with manual reset for protection of material

Additional equipment

  • Exhaust air flap controlled manually or automatically for better ventilation of furnace chamber
  • Fan for better ventilation of combustion chamber and for fast cooling of the furnace
  • Protective gas connector and seal of furnace casing to allow purging of furnace with protective gasses
  • Manual or automatic gas supply system
ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmPowerElectricalWeight
 °Cwdhin LWDHkWconnection*in kg
HFL 16/161600200300260167708301550123-phase¹500
HFL 40/161600300350350408808801710123-phase660
HFL 64/161600400400400649809301830183-phase880
HFL 160/161600500550550160109010802030213-phase1140
            
HFL 16/171700200300260167708301550123-phase¹530
HFL 40/171700300350350408808801710123-phase690
HFL 64/171700400400400649809301830183-phase920
HFL 160/171700500550550160109010802030213-phase1190
¹Heating only between two phases *Please see page 42 for more information about mains voltage

More information

Print