VHT 08/16 MO with hydrogen extension package as automatic version
H2 Version VHT…/MO-H2 or VHT…/GR-H2 for Operation with Hydrogen or other Reaction Gases

In the H2 version the furnaces of the VHT…/MO or VHT…/GR product line can be operated under hydrogen or other reaction gases. For these applications, the systems are additionally equipped with the required safety technology. Only certified and industry proven safety sensors are used. The furnaces are controlled by a fail-safe PLC control system (S7-300F/safety controller).

  • Certified safety concept
  • Automation package (see additional equipment above)
  • Redundant gas inlet valves for hydrogen
  • Monitored pre-pressures of all process gases
  • Bypass for safe purging of furnace chamber with inert gas
  • Pressure-monitored emergency flooding with automated solenoid valve opening
  • Electric or gas-heated exhaust gas torch for H2 post-combustion
  • Atmospheric operation: H2-purging of process reactor starting from room temperature at controlled over pressure (50 mbar relative)

Additional equipment

  • Partial pressure operation: H2 flushing at underpressure in the process reactor starting from 750 °C furnace chamber temperature
  • Retort in the process chamber for debinding under hydrogen

advancedmaterials_englisch catalogue Advanced Materials
(URL: http://www.nabertherm.nl/produkte/advancedmaterials/advancedmaterials_englisch.pdf)